#ifndef SCM_FLUIDS_H
#define SCM_FLUIDS_H
-/* Copyright (C) 1996,2000,2001 Free Software Foundation, Inc.
+/* Copyright (C) 1996,2000,2001, 2006, 2008, 2009, 2010, 2011 Free Software Foundation, Inc.
*
* This library is free software; you can redistribute it and/or
- * modify it under the terms of the GNU Lesser General Public
- * License as published by the Free Software Foundation; either
- * version 2.1 of the License, or (at your option) any later version.
+ * modify it under the terms of the GNU Lesser General Public License
+ * as published by the Free Software Foundation; either version 3 of
+ * the License, or (at your option) any later version.
*
- * This library is distributed in the hope that it will be useful,
- * but WITHOUT ANY WARRANTY; without even the implied warranty of
+ * This library is distributed in the hope that it will be useful, but
+ * WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public
* License along with this library; if not, write to the Free Software
- * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
+ * Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
+ * 02110-1301 USA
*/
\f
#include "libguile/root.h"
#include "libguile/vectors.h"
+/* These "with-fluids" objects live on the dynamic stack, and record previous
+ values of fluids. Guile uses shallow binding, so the current fluid values are
+ always in the same place for a given thread, in the dynamic-state vector.
+ */
+
+#define SCM_WITH_FLUIDS_P(x) (!SCM_IMP (x) && SCM_TYP7(x) == scm_tc7_with_fluids)
+#define SCM_WITH_FLUIDS_LEN(x) (SCM_CELL_WORD ((x), 0) >> 8)
+#define SCM_WITH_FLUIDS_NTH_FLUID(x,n) (SCM_CELL_OBJECT ((x), 1 + (n)*2))
+#define SCM_WITH_FLUIDS_NTH_VAL(x,n) (SCM_CELL_OBJECT ((x), 2 + (n)*2))
+#define SCM_WITH_FLUIDS_SET_NTH_VAL(x,n,v) (SCM_SET_CELL_OBJECT ((x), 2 + (n)*2, (v)))
+
+
/* Fluids.
- Fluids are objects of a certain type (a smob) that can hold one SCM
- value per dynamic state. That is, modifications to this value are
- only visible to code that executes with the same dynamic state as
- the modifying code. When a new dynamic state is constructed, it
- inherits the values from its parent. Because each thread executes
- with its own dynamic state, you can use fluids for thread local
- storage.
-
- Each fluid is identified by a small integer. This integer is used
- to index a vector that holds the values of all fluids. A dynamic
- state consists of this vector, wrapped in a smob so that the vector
- can grow.
+ Fluids are objects of a certain type that can hold one SCM value per
+ dynamic state. That is, modifications to this value are only visible
+ to code that executes with the same dynamic state as the modifying
+ code. When a new dynamic state is constructed, it inherits the
+ values from its parent. Because each thread executes with its own
+ dynamic state, you can use fluids for thread local storage.
+
+ Each fluid is identified by a small integer. This integer is used to
+ index a vector that holds the values of all fluids. A dynamic state
+ consists of this vector, wrapped in an object so that the vector can
+ grow.
*/
-/* The fastest way to acces/modify the value of a fluid. These macros
- do no error checking at all. The first argument is the index
- number of the fluid, obtained via SCM_FLUID_NUM, not the fluid
- itself. You must make sure that the fluid remains protected as
- long you use its number since numbers of unused fluids are reused
- eventually.
-*/
-
-#define SCM_FLUID_NUM(x) scm_i_fluid_num (x)
-#define SCM_FAST_FLUID_REF(n) scm_i_fast_fluid_ref (n)
-#define SCM_FAST_FLUID_SET_X(n, val) scm_i_fast_fluid_set_x ((n),(val))
+#define SCM_FLUID_P(x) (!SCM_IMP (x) && SCM_TYP7 (x) == scm_tc7_fluid)
+#ifdef BUILDING_LIBGUILE
+#define SCM_I_FLUID_NUM(x) ((size_t)(SCM_CELL_WORD_0 (x) >> 8))
+#define SCM_I_FLUID_DEFAULT(x) (SCM_CELL_OBJECT_1 (x))
+#endif
SCM_API SCM scm_make_fluid (void);
+SCM_API SCM scm_make_fluid_with_default (SCM dflt);
+SCM_API SCM scm_make_unbound_fluid (void);
SCM_API int scm_is_fluid (SCM obj);
SCM_API SCM scm_fluid_p (SCM fl);
SCM_API SCM scm_fluid_ref (SCM fluid);
SCM_API SCM scm_fluid_set_x (SCM fluid, SCM value);
-SCM_API size_t scm_i_fluid_num (SCM fl);
-SCM_API SCM scm_i_fast_fluid_ref (size_t n);
-SCM_API void scm_i_fast_fluid_set_x (size_t n, SCM val);
+SCM_API SCM scm_fluid_unset_x (SCM fluid);
+SCM_API SCM scm_fluid_bound_p (SCM fluid);
+
+SCM_INTERNAL SCM scm_i_make_with_fluids (size_t n, SCM *fluids, SCM *vals);
+SCM_INTERNAL void scm_i_swap_with_fluids (SCM with_fluids, SCM dynamic_state);
SCM_API SCM scm_c_with_fluids (SCM fluids, SCM vals,
SCM (*cproc)(void *), void *cdata);
SCM_API SCM scm_with_fluids (SCM fluids, SCM vals, SCM thunk);
SCM_API SCM scm_with_fluid (SCM fluid, SCM val, SCM thunk);
-SCM_API void scm_frame_fluid (SCM fluid, SCM value);
+SCM_API void scm_dynwind_fluid (SCM fluid, SCM value);
+
+#ifdef BUILDING_LIBGUILE
+#define SCM_I_DYNAMIC_STATE_P(x) (!SCM_IMP (x) && SCM_TYP7 (x) == scm_tc7_dynamic_state)
+#define SCM_I_DYNAMIC_STATE_FLUIDS(x) SCM_PACK (SCM_CELL_WORD_1 (x))
+#endif
SCM_API SCM scm_make_dynamic_state (SCM parent);
SCM_API SCM scm_dynamic_state_p (SCM obj);
SCM_API int scm_is_dynamic_state (SCM obj);
SCM_API SCM scm_current_dynamic_state (void);
SCM_API SCM scm_set_current_dynamic_state (SCM state);
-SCM_API void scm_frame_current_dynamic_state (SCM state);
+SCM_API void scm_dynwind_current_dynamic_state (SCM state);
SCM_API void *scm_c_with_dynamic_state (SCM state,
void *(*func)(void *), void *data);
SCM_API SCM scm_with_dynamic_state (SCM state, SCM proc);
-SCM_API SCM scm_i_make_initial_dynamic_state (void);
+SCM_INTERNAL SCM scm_i_make_initial_dynamic_state (void);
-SCM_API void scm_fluids_prehistory (void);
-SCM_API void scm_init_fluids (void);
+SCM_INTERNAL void scm_i_fluid_print (SCM exp, SCM port, scm_print_state *pstate);
+SCM_INTERNAL void scm_i_dynamic_state_print (SCM exp, SCM port, scm_print_state *pstate);
+SCM_INTERNAL void scm_i_with_fluids_print (SCM exp, SCM port, scm_print_state *pstate);
+SCM_INTERNAL void scm_init_fluids (void);
#endif /* SCM_FLUIDS_H */