1 To upgrade from master or edge to the new motion control firmware
2 -----------------------------------------------------------------
3
4 The following changes must be made to your config
5
6 1. ```alpha_max_travel, beta_max_travel, gamma_max_travel``` must be correctly defined for homing to work properly
7 they control the maximum distance the axis will move before it gives up finding the home switch. They are currently set to ```alpha_max, beta_max and Gamma_max``` (or 500) if not found in the config file.
8
9 2. it is best to start from a fresh config
10
11 3. you must delete the config-override (M502) as M203 format has changed (M203 sets cartesian max speeds, M203.1 sets actuator max speeds, no longer uses ABC as these are now reserved for future n-axis). (or for a short while just do M500 as the A B C will be read until it is deprecated, and M500 will save it in the new format)
12
13 4. Homing is slightly different, by default it will home X and Y axis at the same time then Z, this can be reversed and have Z home first then X and Y.
14 the homing_order setting still works the same way as before.
15
16 5. The old extruder syntax is no longer allowed so check your config has the latest extruder config like
17 ```
18 extruder.hotend.enable true # Whether to activate the extruder module at all. All configuration is ignored if false
19 extruder.hotend.steps_per_mm 710 # Steps per mm for extruder stepper
20 extruder.hotend.default_feed_rate 600 # Default rate ( mm/minute ) for moves where only the extruder moves
21 etc
22 ```
23
24 and not the old
25
26 ```
27 extruder_module_enable true
28 ```
29
30 6. If you use volumetric extrusion (M200 D2.85) then note that unlike the current edge, G1 E5 will extrude 5mm³ not 5mm. Note that in slic3r there is now a smootheware flavor you need to select for gcode generation, which fixes an issue with firmware retract.
31
32 7. if you have configured more than 2 extruders you will need to recompile and set ```MAX_ROBOT_ACTUATORS``` accordingly.. https://github.com/Smoothieware/Smoothieware/blob/edge/src/modules/robot/ActuatorCoordinates.h#L17
33
34 The following changes must be made to your hardware
35 ---------------------------------------------------
36
37 1. Due to a mistake in the previous versions of the firmware the E direction was reversed, so you must invert your dir pin for your extruders (or reverse the extruder plug) from how they were before.