information.
--></head><body><div class="refentry"><a id="courierlogger" shape="rect"> </a><div class="titlepage"/><div class="refnamediv"><h2>Name</h2><p>courierlogger — Courier syslog wrapper</p></div><div class="refsynopsisdiv"><h2>Synopsis</h2><div class="cmdsynopsis"><p><code class="command">courierlogger</code> [-name=<em class="replaceable"><code>title</code></em>] [-facility=<em class="replaceable"><code>subsystem</code></em>] [-pid=<em class="replaceable"><code>filename</code></em>] [-user=<em class="replaceable"><code>user</code></em>] [-group=<em class="replaceable"><code>group</code></em>] [-droproot] [[[-respawn] [-start]
- <em class="replaceable"><code>program</code></em> [argument...]] | [-stop] | [-restart]]</p></div></div><div class="refsect1"><a id="idm247890530896" shape="rect"> </a><h2>DESCRIPTION</h2><p>
+ <em class="replaceable"><code>program</code></em> [argument...]] | [-stop] | [-restart]]</p></div></div><div class="refsect1"><a id="idm255241698272" shape="rect"> </a><h2>DESCRIPTION</h2><p>
<span class="command"><strong>courierlogger</strong></span>
is a wrapper that captures
another process's error messages, and forwards them
itself can start another process, and arrange to have its standard error
captured.</p></li></ol></div><p>
</p><p>
-In either case, each read line of text is sent as a syslog message.</p></div><div class="refsect1"><a id="idm247890620896" shape="rect"> </a><h2>OPTIONS</h2><div class="variablelist"><dl class="variablelist"><dt><span class="term">-name=<em class="replaceable"><code>title</code></em></span></dt><dd><p>
+In either case, each read line of text is sent as a syslog message.</p></div><div class="refsect1"><a id="idm255244818160" shape="rect"> </a><h2>OPTIONS</h2><div class="variablelist"><dl class="variablelist"><dt><span class="term">-name=<em class="replaceable"><code>title</code></em></span></dt><dd><p>
Use <em class="replaceable"><code>title</code></em> for sending messages to syslog.
<em class="replaceable"><code>title</code></em> should be the application's name.</p></dd><dt><span class="term">-facility=<em class="replaceable"><code>subsystem</code></em></span></dt><dd><p>
Use <em class="replaceable"><code>subsystem</code></em> for classifying messages.
<span class="command"><strong>courierlogger</strong></span>, capturing its standard error.
Otherwise, <span class="command"><strong>courierlogger</strong></span>
reads message from standard input, and automatically terminates when
-standard input is closed.</p></dd></dl></div></div><div class="refsect1"><a id="idm247885239328" shape="rect"> </a><h2>SEE ALSO</h2><p>
+standard input is closed.</p></dd></dl></div></div><div class="refsect1"><a id="idm255239466800" shape="rect"> </a><h2>SEE ALSO</h2><p>
<a class="ulink" href="couriertcpd.html" target="_top" shape="rect"><span class="citerefentry"><span class="refentrytitle">couriertcpd</span>(1)</span></a>, your syslog man page.</p></div></div></body></html>