Commit | Line | Data |
---|---|---|
d9898ee8 | 1 | <?xml version="1.0"?> |
b0322a85 | 2 | <html xmlns="http://www.w3.org/1999/xhtml"><head><meta http-equiv="Content-Type" content="text/html; charset=UTF-8"/><title>courierlogger</title><link rel="stylesheet" type="text/css" href="style.css"/><meta name="generator" content="DocBook XSL Stylesheets V1.78.1"/><link rel="home" href="#courierlogger" title="courierlogger"/><link xmlns="" rel="stylesheet" type="text/css" href="manpage.css"/><meta xmlns="" name="MSSmartTagsPreventParsing" content="TRUE"/><link xmlns="" rel="icon" href="icon.gif" type="image/gif"/><!-- |
d9898ee8 | 3 | |
b0322a85 | 4 | Copyright 1998 - 2009 Double Precision, Inc. See COPYING for distribution |
d9898ee8 | 5 | information. |
6 | ||
b0322a85 | 7 | --></head><body><div class="refentry"><a id="courierlogger" shape="rect"> </a><div class="titlepage"/><div class="refnamediv"><h2>Name</h2><p>courierlogger — Courier syslog wrapper</p></div><div class="refsynopsisdiv"><h2>Synopsis</h2><div class="cmdsynopsis"><p><code class="command">courierlogger</code> [-name=<em class="replaceable"><code>title</code></em>] [-facility=<em class="replaceable"><code>subsystem</code></em>] [-pid=<em class="replaceable"><code>filename</code></em>] [-user=<em class="replaceable"><code>user</code></em>] [-group=<em class="replaceable"><code>group</code></em>] [-droproot] [[[-respawn] [-start] |
d50284c4 | 8 | <em class="replaceable"><code>program</code></em> [argument...]] | [-stop] | [-restart]]</p></div></div><div class="refsect1"><a id="idm255241698272" shape="rect"> </a><h2>DESCRIPTION</h2><p> |
8d138742 | 9 | <span class="command"><strong>courierlogger</strong></span> |
d9898ee8 | 10 | is a wrapper that captures |
11 | another process's error messages, and forwards them | |
12 | to the system logging facility, | |
b0322a85 | 13 | <span class="quote">“<span class="quote">syslog</span>”</span>.</p><p> |
d9898ee8 | 14 | There are two ways to use courierlogger: |
b0322a85 | 15 | </p><div class="orderedlist"><ol class="orderedlist" type="1"><li class="listitem"><p> |
d9898ee8 | 16 | Use the shell to pipe another command's standard error, and/or its standard |
17 | output, to | |
b0322a85 | 18 | <span class="command"><strong>courierlogger</strong></span>'s standard input.</p></li><li class="listitem"><p> |
d9898ee8 | 19 | Alternatively, |
8d138742 | 20 | <span class="command"><strong>courierlogger</strong></span> |
d9898ee8 | 21 | itself can start another process, and arrange to have its standard error |
22 | captured.</p></li></ol></div><p> | |
23 | </p><p> | |
d50284c4 | 24 | In either case, each read line of text is sent as a syslog message.</p></div><div class="refsect1"><a id="idm255244818160" shape="rect"> </a><h2>OPTIONS</h2><div class="variablelist"><dl class="variablelist"><dt><span class="term">-name=<em class="replaceable"><code>title</code></em></span></dt><dd><p> |
d9898ee8 | 25 | Use <em class="replaceable"><code>title</code></em> for sending messages to syslog. |
26 | <em class="replaceable"><code>title</code></em> should be the application's name.</p></dd><dt><span class="term">-facility=<em class="replaceable"><code>subsystem</code></em></span></dt><dd><p> | |
27 | Use <em class="replaceable"><code>subsystem</code></em> for classifying messages. | |
28 | Your syslog facility uses <em class="replaceable"><code>subsystem</code></em> to determine | |
29 | which log messages are recorded in which log files. | |
b0322a85 | 30 | The currently defined subsystems are:</p><div class="itemizedlist"><ul class="itemizedlist" style="list-style-type: disc; "><li class="listitem"><p><code class="literal">auth</code></p></li><li class="listitem"><p><code class="literal">authpriv</code></p></li><li class="listitem"><p><code class="literal">console</code></p></li><li class="listitem"><p><code class="literal">cron</code></p></li><li class="listitem"><p><code class="literal">daemon</code></p></li><li class="listitem"><p><code class="literal">ftp</code></p></li><li class="listitem"><p><code class="literal">kern</code></p></li><li class="listitem"><p><code class="literal">lpr</code></p></li><li class="listitem"><p><code class="literal">mail</code></p></li><li class="listitem"><p><code class="literal">news</code></p></li><li class="listitem"><p><code class="literal">security</code></p></li><li class="listitem"><p><code class="literal">user</code></p></li><li class="listitem"><p><code class="literal">uucp</code></p></li><li class="listitem"><p><code class="literal">local0</code></p></li><li class="listitem"><p><code class="literal">local1</code></p></li><li class="listitem"><p><code class="literal">local2</code></p></li><li class="listitem"><p><code class="literal">local3</code></p></li><li class="listitem"><p><code class="literal">local4</code></p></li><li class="listitem"><p><code class="literal">local5</code></p></li><li class="listitem"><p><code class="literal">local6</code></p></li><li class="listitem"><p><code class="literal">local7</code></p></li></ul></div><div class="note" style="margin-left: 0.5in; margin-right: 0.5in;"><h3 class="title">Note</h3><p> |
d9898ee8 | 31 | Not all of the above facility names are implemented on every system. |
32 | Check your system's syslog documentation for information on which facility | |
33 | names are allowed, and which log files record the corresponding messages | |
34 | for each facility.</p></div></dd><dt><span class="term">-pid=<em class="replaceable"><code>filename</code></em></span></dt><dd><p> | |
8d138742 | 35 | Save <span class="command"><strong>courierlogger</strong></span>'s |
d9898ee8 | 36 | process ID in <em class="replaceable"><code>filename</code></em>. |
37 | The <em class="parameter"><code>-pid</code></em> option is required when | |
38 | <em class="parameter"><code>-start</code></em>, | |
39 | <em class="parameter"><code>-stop</code></em>, | |
40 | <em class="parameter"><code>-restart</code></em> are given. If <em class="parameter"><code>-pid</code></em> | |
41 | is given without any of these, <em class="parameter"><code>-start</code></em> is assumed.</p></dd><dt><span class="term">-start</span></dt><dd><p> | |
42 | Run as a daemon. The <code class="option">pid</code> option is required. | |
8d138742 CE |
43 | <span class="command"><strong>courierlogger</strong></span> will quietly terminate if another |
44 | <span class="command"><strong>courierlogger</strong></span> process is already running. | |
d9898ee8 | 45 | This is used to make sure that only one instance of |
46 | <code class="filename">program</code> is running at the same time. | |
47 | Specify a different filename with <code class="option">pid</code> to start a second | |
48 | copy of <code class="filename">program</code>.</p></dd><dt><span class="term">-respawn</span></dt><dd><p> | |
49 | Restart <code class="filename">program</code> if it terminates. | |
50 | Normally | |
8d138742 | 51 | <span class="command"><strong>courierlogger</strong></span> itself will terminate when |
d9898ee8 | 52 | <code class="filename">program</code> finishes running. |
53 | Use <code class="option">respawn</code> to restart it instead.</p></dd><dt><span class="term">-restart</span></dt><dd><p> | |
54 | Send a <code class="literal">SIGHUP</code> signal to the courierlogger process | |
55 | (as determined by examining the contents of the file specified by | |
56 | <code class="option">pid</code>), which will in turn send a <code class="literal">SIGHUP</code> | |
57 | to its child <code class="filename">program</code>. | |
58 | Does nothing if courierlogger is not running.</p><div class="note" style="margin-left: 0.5in; margin-right: 0.5in;"><h3 class="title">Note</h3><p> | |
59 | <code class="filename">program</code> must be originally started with the | |
60 | <code class="option">respawn</code> option if sending it a <code class="literal">SIGHUP</code> | |
61 | causes it to terminate.</p></div><p> | |
62 | The same thing may be accomplished by sending <code class="literal">SIGHUP</code> | |
8d138742 | 63 | to <span class="command"><strong>courierlogger</strong></span> itself.</p></dd><dt><span class="term">-stop</span></dt><dd><p> |
d9898ee8 | 64 | Send a <code class="literal">SIGTERM</code> signal to courierlogger, which in turn |
65 | forwards it on to <code class="filename">program</code>. | |
66 | If <code class="filename">program</code> does not terminate in 8 seconds, kill it | |
67 | with <code class="literal">SIGKILL</code>.</p></dd><dt><span class="term">-user=<em class="replaceable"><code>user</code></em>, -group=<em class="replaceable"><code>group</code></em></span></dt><dd><p> | |
68 | If running as root, change credentials to the given user and/or group, which | |
69 | may be given as names or numeric ids.</p><p>When running a child program, it is started | |
70 | <span class="emphasis"><em>before</em></span> privileges are dropped | |
71 | (unless the <code class="option">-droproot</code> option is also given). | |
72 | This gives a means of | |
73 | starting a child as root so it can bind to a privileged port, but still have | |
74 | courierlogger run as a non-root user. For the <code class="option">-stop</code> and | |
75 | <code class="option">-restart</code> options to work, you should configure the child | |
76 | program to drop its privileges to the same userid too.</p></dd><dt><span class="term">-droproot</span></dt><dd><p> | |
77 | Drop root privileges before starting the child process. | |
78 | The <code class="option">-user</code> and <code class="option">-group</code> options specify | |
79 | the non-privileges userid and groupid. | |
80 | Without the <code class="option">-droproot</code> option the child process remains | |
8d138742 | 81 | a root process, and only the parent <span class="command"><strong>courierlogger</strong></span> |
d9898ee8 | 82 | process drops root privileges.</p></dd><dt><span class="term"><em class="replaceable"><code>program</code></em> [ argument ] ... </span></dt><dd><p> |
83 | If a program is given <code class="filename">program</code> | |
84 | will be started as a child process of | |
8d138742 CE |
85 | <span class="command"><strong>courierlogger</strong></span>, capturing its standard error. |
86 | Otherwise, <span class="command"><strong>courierlogger</strong></span> | |
d9898ee8 | 87 | reads message from standard input, and automatically terminates when |
d50284c4 | 88 | standard input is closed.</p></dd></dl></div></div><div class="refsect1"><a id="idm255239466800" shape="rect"> </a><h2>SEE ALSO</h2><p> |
8d138742 | 89 | <a class="ulink" href="couriertcpd.html" target="_top" shape="rect"><span class="citerefentry"><span class="refentrytitle">couriertcpd</span>(1)</span></a>, your syslog man page.</p></div></div></body></html> |