#temperature_control.hotend.max_temp 300 # Set maximum temperature - Will prevent heating above 300 by default\r
#temperature_control.hotend.min_temp 0 # Set minimum temperature - Will prevent heating below 0 by default\r
\r
+# safety control is enabled by default and can be overidden here, the values show the defaults\r
+#temperature_control.hotend.runaway_heating_timeout 900 # max is 2040 seconds, how long it can take to heat up\r
+#temperature_control.hotend.runaway_cooling_timeout 0 # max is 2040 seconds, how long it can take to cool down if temp is set lower\r
+#temperature_control.hotend.runaway_range 20 # Max setting is 63°C\r
+\r
temperature_control.hotend.p_factor 13.7 #\r
temperature_control.hotend.i_factor 0.097 #\r
temperature_control.hotend.d_factor 24 #\r